H90 and DMC.micro PRO

Home Forums Products Stompboxes H90 and DMC.micro PRO

Viewing 2 reply threads
  • Author
    Posts
    • #172844
      carouzal
      Participant

        I am trying to get my DMC.micro to change presets on the H90.

        I have device A set to eventide and it changes presets but the active bypass is not working correctly.

        It seems to be sending CC42 127 on activate and CC42 0 on bypass.

        I have to h90 set to CC42 for Program Active/Bypass toggle but it only toggles on the 127 value being sent.

        I don’t see how to make this work. Anyone have any experience with this?

      • #172861
        joecozzi
        Moderator
        Eventide Staff

          Hi carouzal,

          While I don’t have experience with the Micro directly, I can tell you that whenever you’ve assigned P, A, or B act/bypass commands a CC#, sending a value of zero does nothing. Only values greater than 64 will toggle act/byp states. Only act/byp (M) commands allow respond to value=0 where 63 or less is OFF and 64 and above is ON. Hope that helps.

        • #172877
          carouzal
          Participant

            Thanks, that mirrors what I am seeing. I also have an email in to disaster area designs to see what can be done on the DMC.micro side of things.

        Viewing 2 reply threads