H9000 wordclock THRU?

Home Forums Products Rackmount H9000 wordclock THRU?

Viewing 3 reply threads
  • Author
    Posts
    • #194316
      wilkinsi
      Participant

        Is it possible to daisy chain word clock devices with the H9000 mid-chain by using both wordclock in and out instead of having to use a BNC T adapter? I just tried this and I don’t think you can. I tried putting something from the H9000 output to another audio interface and the latter will not clock to the H9000.

      • #194317
        tbskoglund
        Keymaster
        Eventide Staff

          That should work.

          What is the exact setup and settings you tried?

          H9000 clock should be set to “Word Clock”.

          Does the interface clock to the H9000 correctly if clock is set to “Internal”?

        • #194318
          wilkinsi
          Participant

            In the end, I just put the H9000R last in the wordclock chain and set the 2nd audio interface wordclock output to Thru. I am using the ADAT and USB ports, so trying to stick a BNC T-adapter in there as well impossible at the moment. If I later add another word closk device, I may have to buy a work clock generator…

             

          • #194319
            tbskoglund
            Keymaster
            Eventide Staff

              Ok, I’m still not sure why that wasn’t working for you.

              I’ve setup the H9000 as a Wordclock THRU device before and it worked.

              Note that you can also clock the H9000 via ADAT so you may not even need to have it hooked up to your WC chain. It will clock to your interface via the ADAT connection.

          Viewing 3 reply threads