Home › Forums › Products › Rackmount › Eclipse 4.04 — Remote MIDI SysEx YES/NO confirmation during SAVE AS overwrite
- This topic has 0 replies, 1 voice, and was last updated 1 week, 1 day ago by
mrkeeny.
-
AuthorPosts
-
-
November 12, 2026 at 7:44 pm #207384
I’m developing a standalone MIDI patch browser and editor for the Eventide Eclipse using an Electra One MkII controller.
Almost everything is now working, including programme browsing/loading, dynamic parameter editing, reading values, selecting internal save destinations and triggering SAVE AS remotely.
However, I’ve encountered one remaining problem: I cannot remotely confirm the YES/NO overwrite prompt when saving to an occupied internal programme slot.
Hardware/software:
Eventide Eclipse, firmware 4.04
Electra One MkII, firmware 5.0.6
MIDI channel 3, SysEx device ID 1
Connection via iConnectivity mioXL
What works:Remote SAVE AS using SysEx VALUE_PUT (0x2D) on object 40050001.
Selecting the destination through object 40050007, with successful readback verification.
Saving to an empty internal programme slot without any problems.
Remote front-panel soft-key commands using the protocol documented in Eventide Technical Note #98.
Sending the SOFT2 command on the normal SAVE AS screen successfully opens the NAME editor.
The problem:When SAVE AS targets an occupied slot, the Eclipse correctly displays its YES/NO overwrite confirmation.
I’ve captured the SysEx generated by pressing the physical YES and NO buttons and reproduced those messages from the Electra:
YES:
1C 70 01 01 0F 0F 0F 0B 0F 0F 0F 0FNO:
1C 70 01 01 0F 0F 0F 0F 0F 0B 0F 0FEach is followed by the all-keys-released message:
1C 70 01 01 0F 0F 0F 0F 0F 0F 0F 0F
I’ve tested different press durations (120 ms and 250 ms), along with repeated presses. The Eclipse does not appear to acknowledge either remote confirmation command, even though the same remote soft-key mechanism works elsewhere.
Interestingly, ordinary SysEx parameter read requests also stop receiving responses while the overwrite confirmation is displayed. Communication resumes once the dialog is dismissed using the physical Eclipse controls.
I’ve also tested the physical ENTER button at the overwrite confirmation, but it does not confirm the save.
My questions:
Does Eclipse firmware 4.04 intentionally ignore incoming MIDI SysEx remote-key commands while a YES/NO confirmation dialog is active?
Is there a different MIDI command or mechanism for remotely responding to these confirmation prompts?
Is there a documented way to overwrite a single occupied internal programme slot remotely without using the front-panel confirmation?
Has anyone encountered and solved this when developing Eclipse, Orville or H-series MIDI remote controllers?
I’m keen to complete this as a fully standalone controller without needing to touch the Eclipse front panel.Any advice, particularly from Eventide engineering or anyone familiar with the Eclipse’s MIDI implementation, would be greatly appreciated.
-
-
AuthorPosts